Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 438
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2021  |  Volume : 18  |  Issue : 1  |  Page : 48

Microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel–titanium endodontic instruments


1 Department of Integrated Basic Studies, Laboratory of Immunodetection and Bioanalysis, Faculty of Dentistry, University of Antioquia, Medellin, Colombia
2 Biomaterials Research Group, Bioengineering Program, Engineering Faculty, University of Antioquia, Medellin, Colombia

Correspondence Address:
Prof. Sergio Iván Tobón-Arroyave
Laboratory of Immunodetection and Bioanalysis, Faculty of Dentistry, University of Antioquia, Calle 70 N° 52-21, Medellín
Colombia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1735-3327.318943

Rights and Permissions

Background: Nickel–titanium (NiTi) instruments have represented a great technological development that enabled endodontists conforming irregular-shaped root canals. Notwithstanding, the repeated use of these instruments may lead to the fracture without any prior visible warning signs. This study aimed to evaluate how multiple clinical instrumentation/sterilization cycles of two NiTi mechanized instruments can affect their microstructural, microchemical, and mechanical characteristics. Materials and Methods: In this observational descriptive study, a total of 140 NiTi instruments, 70 ProTaper Gold® (PTG) and 70 WaveOne Gold® (WOG) were analyzed. For each brand system, instruments were evaluated in the as-received condition (n = 10) and after one (n = 20), two (n = 20), and three (n = 20) instrumentation/sterilization cycles. Intraoperative instrumentation parameters were recorded for all used instruments. Afterward, the files were examined using scanning electron microscopy and energy-dispersive X-ray microanalysis. All of the instruments were tensile-fatigue tested until rupture in order to calculate the mechanical tensile strength and the maximum elongation percentage for the samples. Statistical analysis was completed using Chi-square, Kruskal–Wallis H-, or Mann–Whitney U-tests with a statistical significance set at P < 0.05. Results: Significant increasing changes in surface topography (P < 0.05, Chi-square test) and chemical composition (P < 0.05, Kruskal–Wallis H-test) in both brand systems through instrumentation/sterilization cycles were detected. In addition, values of mechanical tensile strength and maximum elongation percentage increased significantly through instrumentation/sterilization cycles in the PTG group, whereas only the median values of mechanical tensile strength increased significantly in the WOG group (all P < 0.01, Kruskal–Wallis H-test). Conclusion: Although multiple instrumentation/sterilization cycles may render NiTi instruments more flexible and fatigue resistant, the significant changes detected in their surface topography and chemical composition should preclude their repeated clinical use in the routine endodontic practice as prevention for breakage.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed643    
    Printed16    
    Emailed0    
    PDF Downloaded135    
    Comments [Add]    

Recommend this journal