Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 1704
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2021  |  Volume : 18  |  Issue : 1  |  Page : 96

Effect of curing method and thermocycling on flexural strength and microhardness of a new composite resin with alkaline filler


1 Dental and Periodontal Research Center; Department of Operative Dentistry, Dental Faculty, Tabriz Medical Sciences University, Tabriz, Iran
2 Department of Operative Dentistry, Dental Faculty, Tabriz Medical Sciences University, Tabriz, Iran

Correspondence Address:
Dr. Mohammad Esmaeel Ebrahimi Chaharom
Department of Operative Dentistry, Dental Faculty, Tabriz Medical Sciences University, Daneshgah Ave, Tabriz
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1735-3327.330877

Rights and Permissions

Background: Cention N has been introduced as an alternative material for amalgam. The purpose was to investigate the flexural strength and microhardness of this material in self-cure and dual-cure modes before and after thermocycling. Materials and Methods: In this experimental study, 40 samples of Cention N were prepared in order to determine and compare the microhardness. Half of the samples were set by self-cure method and the other half with dual-cure method. The Vickers microhardness test was performed once after 24 h and again after 10000 thermocyclings. Three-point flexural test was used to determine and compare the flexural strength of 52 rod-shaped samples. Half of the samples were set by self-cure method and the other half with dual-cure method. Among 26 samples in each group, 13 samples were randomly selected and three-point flexural test was performed after 24 h and for another 13 samples after 10,000 thermocyclings. Data were analyzed using two-way ANOVA and paired samples t-test (P < 0.05). Results: There was a statistically significant difference between the mean of microhardness values in two curing methods (P < 0.001) and in two storage conditions (P < 0.001). The mean of dual-cure microhardness (100.99 ± 7.22) was higher than that of self-cure (64.61 ± 12.51) and the mean value associated with pre-thermocycling (89.75 ± 15.84) was higher than that of the post-thermocycling (76.44 ± 23.56). There was no statistically significant difference between the mean flexural strength in the two curing methods (self-cure [72.85 ± 16.26], dual cure [79.87 ± 23.07]; [P > 0.05]). However, the mean flexural strength without thermocycling (85.98 ± 21.74) was higher than that of the thermocycled group (64.24 ± 6.40) (P < 0.001). Conclusion: The microhardness of Cention N in dual-cure mode was higher than that of self-cure mode, but the flexural strength of dual-cure was not significantly different from that of self-cure. Thermocycling had a significant effect on the microhardness and flexural strength.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2760    
    Printed84    
    Emailed0    
    PDF Downloaded452    
    Comments [Add]    
    Cited by others 3    

Recommend this journal