Effect of immersion in sodium hypochlorite on cyclic fatigue resistance of RaCe, HyFlex CM and XP-endo shaper files


Department of Endodontics, School of Dentistry, Islamic Azad University, Isfahan (Khorasgan) Branch, Isfahan, Iran

Correspondence Address:
Dr. Amin Mortaheb
Department of Endodontics, School of Dentistry, Isfahan (Khorasgan) Branch, Islamic Azad University, Isfahan
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1735-3327.351346

Rights and Permissions

Background: This study assessed the effect of sodium hypochlorite on cyclic fatigue resistance of RaCe, HyFlex CM and XP-endo Shaper files. Materials and Methods: In this in vitro, experimental study, 90 RaCe, HyFlex CM and XP-endo Shaper files (n = 30 of each) were divided into two groups (n = 45). Group 1 included 15 files of each rotary system, which were immersed in 37°C sodium hypochlorite (5.25%) for 5 min. Group 2 files were immersed in 37°C saline for 5 min. The files underwent cyclic fatigue testing using simulated root canals in which, the rotary files could freely rotate until fracture. Time of fracture was recorded by a chronometer and the number of cycles until fracture was calculated. Data were analyzed using two-way ANOVA and Bonferroni test (α = 0.05). Results: No significant difference existed in the mean number of cycles or rotation time of files between saline and sodium hypochlorite (P > 0.05). The mean rotation time of RaCe was significantly shorter than that of HyFlex and XP-endo Shaper in both solutions (P < 0.05). The mean number of cycles of RaCe was significantly lower than that of HyFlex and XP-endo Shaper files in both solutions (P < 0.05). The mean number of cycles of HyFlex was significantly lower than that of XP-endo Shaper (P < 0.05). >Conclusion: Immersion of rotary files made of different alloys in 5.25% sodium hypochlorite for 5 min had no effect on their fracture resistance. However, type of file alloy affected its fatigue resistance such that XP-endo Shaper showed the highest and RaCe showed the lowest fatigue resistance.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed324    
    Printed2    
    Emailed0    
    PDF Downloaded41    
    Comments [Add]    

Recommend this journal