Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 938
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2022  |  Volume : 19  |  Issue : 1  |  Page : 65

Evaluation of internal fit of press ceramic and porous structured cobalt–chromium crown fabricated by additive manufacturing


1 3D Printer Team, Cybermed Inc., Yuseong-gu, Daegeon, Republic of Korea
2 Department of Dental Laboratory Science and Engineering, Korea University, Seongbuk-gu, Seoul, Republic of Korea
3 Department of Mechanical Robotics and Energy Engineering, Dongguk University, Jung-Gu, Seoul, Republic of Korea

Correspondence Address:
Dr. Joong Yeon Lim
Dongguk University, Pildong-ro 1-Gil 30, Jung-Gu, Seoul 04620
Republic of Korea
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1735-3327.353834

Rights and Permissions

Background: The purpose of this in vitro study is to fabricate a novel metal–ceramic prosthesis with a porous structure, to compensate for the disadvantages associated with the design of existing prostheses, and to measure the internal fit of this prosthesis. Materials and Methods: In this in vitro study, the mandibular first molar was scanned from the dental computer-aided-design to design a 3 mm porous structure frame. The frame was produced using the lamination method and fired in a pressed ceramic. For comparison, pore-free specimens were fabricated by selective laser sintering (SLS) as described above, and porous specimens were fabricated by casting (total n = 30). The internal fit was then measured using a digital microscope (at 100× magnification), and the data were analyzed using one-way ANOVA (α = 0.05). Results: The total mean internal discrepancies for each group were 42.32 ± 22.50 μm for the porous structure SLS group (PS-group), 107.54 ± 38.75 μm for no-porous casting group (group), and 121.36 ± 50.19 μm for the no-porous SLS group (group), with significant differences (P < 0.05) among all groups. Conclusion: The internal discrepancies of porous structure crown fabricated by SLS were smaller than that of no-porous crown fabricated by casting and SLS. Based on these laboratory findings, further studies should be conducted to evaluate the feasibility of the newly designed porous structure and press ceramic prosthesis to determine whether they can be applied in clinical practice.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1190    
    Printed46    
    Emailed0    
    PDF Downloaded179    
    Comments [Add]    

Recommend this journal