Materials and Methods: This in vitro, experimental study evaluated 20 endocrowns, of which 10 were fabricated by 3D printing and 10 were fabricated by the conventional wax-up technique. The marginal gap was measured at 8 points under a stereomicroscope. The results were analyzed using the Shapiro–Wilk test, paired t-test, independent t-test, and one-way analysis of variance (α = 0.05). Results: The mean marginal gap was maximum at the distal point, and minimum at the buccal point for the conventionally fabricated endocrowns with an overall mean marginal gap of 99.67 ± 4.59 μm. The mean marginal gap was maximum at the mesiobuccal and minimum at the buccal point before pressing (overall mean of 103.92 ± 2.19 μm) before pressing, and maximum at the distobuccal and minimum at the mesiobuccal point after pressing (overall mean of 117.67 ± 2.87 μm). According to paired t-test, the mean marginal gap of endocrowns fabricated by 3D printing significantly increased after pressing at all 8 points and also in general, compared with before pressing (P < 0.001). Furthermore, the mean marginal gap at all points was significantly greater in endocrowns fabricated by 3D printing compared with those fabricated by the conventional method (independent t-test, P < 0.001). Conclusion: Within the limitations of this in vitro study, the results showed that endocrowns fabricated by the conventional method had significantly superior marginal fit than those fabricated by 3D printing. Background: Marginal fit is a key factor in success of prosthetic restorations. This study aimed to assess and compare the marginal fit of endocrowns fabricated by three-dimensional (3D) printing and the conventional method.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed316    
    Printed10    
    Emailed0    
    PDF Downloaded49    
    Comments [Add]    

Recommend this journal