Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 1044
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2023  |  Volume : 20  |  Issue : 1  |  Page : 62

Stress analysis in implant, abutment, and peripheral bone with different restorative crown and abutment materials: A three-dimensional finite element analysis study


1 Department of Prosthodontics, Manav Rachna Dental College, Faridabad, Haryana, India
2 Private Practitioner, Meerut, Uttar Pradesh, India
3 Department of Prosthodontics, I.P College, Ghaziabad, Uttar Pradesh, India
4 Department of Prosthodontics, ITS-CDSR, Ghaziabad, Uttar Pradesh, India

Correspondence Address:
Dr. Sapna Rani
House No. 2062, Sec 7D, Faridabad - 121 006, Haryana
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1735-3327.377582

Rights and Permissions

Background: Stresses on prosthetic crown directly influences the survival rate of implants hence it should be considered while selecting prosthetic material. The aim of the study is to evaluate stress analysis on implant, abutment and peripheral bone with change in different abutment and different crown materials by 3D finite element study. Materials and Methods: A numerical procedure based on finite element method was adopted to investigate the influence of different prosthetic materials and abutment materials on stress situation. Eight different three-dimensional (3D) models of a bone-level implant system and an abutment were created by using the standard tessellation language (STL) data of original implant components. Combinations included of abutment materials i.e., Titanium (Ti), Polyetheretherketone (PEEK), Polyetherketoneketone (PEKK), Polymer infilterated hybrid ceramic (TZI) along with different restoration materials Monolithic Zirconia (MZ) and lithium disilicate glass ceramic (IPS e-max). In each model, the implants were loaded obliquely (150 N). The stress distribution in the implant, Abutment and peripheral bone was evaluated through the von Mises stress analysis. Results: Higher stresses were found on neck of implants irrespective of abutment material and restorative material. Highest stress was found with PEEK material. The pattern of stress distribution in implant and peripheral bone was similar in all models. Conclusion: There is no difference in stresses with the change in restorative material but the change in abutment material has effect on stresses on implants.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed637    
    Printed44    
    Emailed0    
    PDF Downloaded65    
    Comments [Add]    

Recommend this journal