Dental Research Journal

ORIGINAL ARTICLE
Year
: 2021  |  Volume : 18  |  Issue : 1  |  Page : 108-

Evaluation of stress distribution of porous tantalum and solid titanium implant-assisted overdenture in the mandible: A finite element study


Ayshin Akbarzadeh1, Yasser Hemmati1, Fariba Saleh-Saber2 
1 Department of Prosthodontics, Dental Faculty, Urmia University of Medical Science, Urmia, Iran
2 Department of Prosthodontics, Dental Faculty, Tabriz University of Medical Science, Tabriz, Iran

Correspondence Address:
Dr. Yasser Hemmati
Department of Prosthodontics, Urmia Dental Faculty, Alborz AVE, Post Code: 5714783734, Urmia
Iran

Aims: The present study aimed to evaluate the stress distribution of porous tantalum implant and titanium solid implant assisted overdenture (IAO) in mandibular bone by utilizing three-dimensional (3D) finite element (FE) analysis. Materials and Methods: In this FE study, an existing cone-beam volumetric tomography scan of a patient without any maxillofacial anomaly with an available acceptable IAO for mandible was used to attain the compartments of a completely edentulous mandible. Zimmer trabecular implants and locator attachment systems were selected as the case group (Model B), and Zimmer Screw-Vent implants and locator attachment system were chosen for the control (Model A), as overdenture attachments in the present study. The mandibular overdenture was scanned and digitized as a FE model. Two 3D FE models were designed as edentulous lower jaws, each with four implants in the anterior section of the mandible. Three forms of loads were directed to the IAO in each model: Vertical loads on the left first molar vertical molar (VM). Vertical loads on the lower incisors (VI). Inclined force buccolingually applied at left first molar (IM). Results: Under all loading conditions, the maximum strain values in peri-implant bone in Model A were less than Model B. Under VI, the greatest stress value around abutments in both models was about 2–3 times higher than the other loads. Under VM and IM loads, no significant difference was observed between models. Conclusion: Using trabecular metal implants instead of solid implants reduces strain values around both cortical and trabecular bone.


How to cite this article:
Akbarzadeh A, Hemmati Y, Saleh-Saber F. Evaluation of stress distribution of porous tantalum and solid titanium implant-assisted overdenture in the mandible: A finite element study.Dent Res J 2021;18:108-108


How to cite this URL:
Akbarzadeh A, Hemmati Y, Saleh-Saber F. Evaluation of stress distribution of porous tantalum and solid titanium implant-assisted overdenture in the mandible: A finite element study. Dent Res J [serial online] 2021 [cited 2023 Sep 25 ];18:108-108
Available from: https://www.drjjournal.net/article.asp?issn=1735-3327;year=2021;volume=18;issue=1;spage=108;epage=108;aulast=Akbarzadeh;type=0